    Model Number : HLT Series
    Certification : CTI/ISO9001:2008
    • Product Details
    • Company Profile

    Stainless Steel Induced Draft Cross Flow Open Circuit Cooling Tower

    Stainless Steel Induced Draft Cross Flow Cooling Tower Open Circuit Cooling Tower

    Cooling Tower Quality Control:

    Under standard working conditions, the circulating cooling water volume, cooling effect and operating noise are ensured. During the manufacturing process of the cooling tower, each process of the product is strictly controlled in accordance with the ISO9001 quality system assurance model standard to ensure its operating effect and ensure that unqualified products do not flow into the next process. Before the cooling tower leaves the factory, a trial run is carried out to detect its noise and wind speed, so that the various indicators of the product meet the user's requirements.

    Cooling Tower Specification:

    Model Volume Temp Difference ℃ Dimension Fan User-made Pipe Valve Noise dB(A)

    Weight

    kg

    Weight kg

    28℃

    27℃ L×W×H Air Volume ( Ten Thousand) m3/h

    Diameter

    cm

    Power kw

    Trans

    mission

    Number

    Water inlet pipe

    mm

    Water distribution

    mm

    Water outlet mm

    Water supply

    mm

    Overflow pipe

    mm

    Drainage outlet mm

    10

    10

    12

    5 1700×850×1250 0.60 500 0.37 Direct

    1

    40

    32x2

    65

    25

    30

    30

    50 200 450
    6 1700x850×1500 0.72 600 0.75 210 460
    10 1700x850×1750 1.05 700 0.75 220 470
    25 1700×850×2000 1.80 700 1.5 230 480

    15

    15

    18

    5 1800x950x1500 0.72 600 0.55 Direct

    1

    50

    40x2

    65

    25

    30

    30

    50 230 530
    6 1800x950×1750 1.05 700 0.75 240 540
    10 1800×950x2000 1.80 700 1.10 260 560
    25 1800×950×2250 2.70 800 1.5 280 580

    20

    20

    25

    5 1900×1150x1750 1.05 700 0.75 Direct

    1

    65

    50×2

    80

    25

    40

    30

    ∠50 320 870
    6 1900x1150×2000 1.25 800 0.75 340 800
    10 1900x1150×2250 1.8 800 1.10 360 910
    25 1900×1150×2500 3.2 800 1.5 380 930

    30

    30

    a5

    5 2100x1150×2000 1.8 800 1.10 Direct

    1

    65

    50x2

    80

    25

    40

    40

    50 350 950
    6 2100x1250×2250 2.2 900 1.10 380 980
    10 2100×1250×2500 3.3 900 1.5 400 1000
    25 2100×1250×2700 4.4 1000 2.2 450 1050

    50

    50

    55

    5 2800x1450×2250 3.3 1000 1.1 Direct

    1

    80

    65×2

    100

    40

    50

    50

    50 750 1450
    6 2800x1450x2500 3.8 1200 1.5 760 1510
    10 2800x1450×2750 4.8 1200 2.2 820 1600
    25 2800×1450×2900 6.5 1200 2.2 900 1700

    Model Volume Temp Difference Dimension Fan User-made Pipe Valve Noise dB(A)

    Weight

    kg

    Weight

    kg

    28℃ 27℃ L×W×H

    Air Volume

    ( Ten Thousand) m3/h

    Diameter

    cm

    Power kw

    Trans

    mission

    Number

    Water inlet pipe

    mm

    Water distribution

    mm

    Water outlet mm

    Water supply

    mm

    Overflow pipe

    mm

    Drainage outlet mm

    B0

    80

    90

    5 3500×1700×3000 5.4 1200 2.2 Direct

    1

    100

    80×2

    125

    40

    50

    50

    ∠51 890 1900
    6 3500×1700x3200 6.2 1500 3.0 1000 2100
    10 3500×1700×3600 6.5 1500 3.0 1300 2400
    25 3500×1700×4100 7.2 1500 4.0 1500 2600

    100

    100

    115

    5 3800×2100x3000 6,5 1500 3.0 Direct

    1

    125

    100x2

    150

    40

    50

    50

    ∠51 1050 2550
    6 3800×2100×3100 6.8 1800 3.0 1200 2600
    10 3800×2100×3600 7.5 1800 4.0 1500 2750
    25 4000×2300×4100 10.5 2000 5.5 1800 2950

    125

    125

    140

    5 3800×2400×3000 7.2 1500 3.0 Direct

    1

    125

    100×2

    150

    40

    50

    50

    ∠52 1300 2650
    6 3800×2400×3100 9.7 1800 4.0 1400 2700
    10 3800×2400×3600 10.5 1800 4.0 1600 2950
    25 4000x240084100 13.6 2000 5.5 2000 3350

    150

    150

    170

    5 4000×2700×3000 8.5 1800 4.0 Direct

    1

    150

    125×2

    200

    40

    50

    50

    ∠52 1400 2850
    6 4000×2700×3100 9.7 2000 4.0 1650 3100
    10 4200×2700×3600 13.6 2000 5.5 2000 3450
    25 4400×2700×4100 16.0 2400 7.5 2400 4150

    175

    175

    180

    5 4000×2800×3000 9.0 1800 4.0

    Direct

    Reduce

    1

    150

    125×2

    200

    40

    50

    50

    ∠50 1800 3400
    6 4200×2800x3100 9.8 2000 5.5 1900 3550
    10 4200×2800×3600 14.0 2000 5.5 2400 3900
    25 4400×2800×4100 16.0 2400 7,5 2700 4300

    200

    200

    230

    5 4200×3000×3000 12.2 2000 5.5

    Direct

    Reduce

    1

    200

    125×2

    250

    40

    50

    50

    53 1950 3600
    6 4200x3000×3100 13.0 2000 5.5 2100 3780
    10 4400×3000×3600 16.2 2400 7.5 2400 4250
    25 4800×3200×4100 18.0 2800 11.0 2700 4750

    250

    250

    280

    5 4400x3300x3000 13.6 2400 7.5 Reduce

    1

    200

    150×2

    250

    40

    65

    65

    56 2400 4470
    6 4400x3300×3100 16.2 2400 7.5 2600 4700
    10 4800×3300×3600 18.5 2800 11.0 2700 4900
    25 4800x3300x4100 20.5 2800 11.0 2900 5300

    300

    300

    320

    5 4800x3900x3000 16.2 2800 7.5 Reduce

    1

    250

    150×2

    300

    40

    65

    65

    ∠56 2700 5450
    6 4800x3900×3100 18.6 2800 11.0 2900 5650
    10 5000x3900x3600 18.6 3000 11.0 3000 5900
    25 5200×3900×4100 20.5 3200 11.0 3150 6700

    350

    350

    375

    5 4000x5600x3000 18,6 1800 4.0

    Direct

    Reduce

    2

    250

    125×4

    200×2

    40×2

    50x2

    50×2

    ∠56 3100 6900
    6 4200×5600x3000 20.5 2000 5.5 3180 7300
    10 4200×5600x3600 23.0 2000 5.5 3450 7800
    25 4400x5600×4100 25.8 2400 7.5 3900 8500

    400

    400

    430

    5 4200×6000×3000 25.0 2000 5.5

    Direct

    Reduce

    2

    200

    125×4

    250×2

    40×2

    50x2

    50x2

    59 3300 7200
    6 4200×6000×3100 27.0 2000 5.5 3500 7500
    10 4400×6000×3600 32.0 2400 7.5 3950 7700
    25 4800×6400×4100 40.0 2800 11.0

    4200

    8000

    Model Volume

    Temp Difference

    Dimension Fan User-made Pipe Valve Noise dB(A)

    Weight

    kg

    Weight

    kg

    28℃ 27℃ L×W×H Air Volume ( Ten Thousand) m3/h

    Diameter

    cm

    Power kw

    Trans

    mission

    Number

    Water inlet pipe

    mm

    Water distribution

    mm

    Water outlet mm

    Water supply

    mm

    Overflow pipe

    mm

    Drainage outlet mm

    450

    450

    480

    5 4000×8100×3000 25.0 1800 4.0

    Direct

    Reduce

    3

    300

    125×6

    200x3

    40×3

    50×3

    50×3

    ∠59 4050 8400
    6 4000x8100x3100 29.0 1800 4.0 4200 8500
    10 4200×8100×3600 40.0 2000 5,5 4500 9000
    25 4400x8100x4100 48.0 2400 7.5 4900 10000

    500

    500

    550

    5 4400×6600×3000 27.0 2400 7.5 Reduce

    2

    300

    150×4

    250×2

    40×2

    65×2

    65×2

    ∠60 4100 8600
    6 4400x6600x3100 32.0 2400 75 4250 9000
    10 4800×6600×3600 38.0 2800 11.0 4600 11000
    25 4800x6000x4100 52.0 2800 11.0 4960 11500

    600

    00

    650

    5 4200×9000×3000 32.5 2000 5.5

    Direct

    Reduce

    3

    350

    125×6

    250×3

    40x4

    50×3

    50x3

    ∠61 4650 10500
    6 4200x9000x3100 40.0 2000 5.5 4800 11000
    10 4400×9000×3600 45.5 2400 7.5 5300 12500
    25 4800x9600×4100 60.0 2800 11.0 5900 13000

    700

    700

    750

    5 4000×11200×3000 40.0 1800 4.0

    Direct

    Reduce

    4

    350

    125x8

    200×4

    40×4

    50×4

    50×4

    ∠62 6100 13000
    6 4200×11200x3100

    45.5

    2000 5.5 6250 13500
    10 4200×11200x3600 52.5 2000 5.5 6700 14000
    25 4400×11200×4100 70.0 2400 7.5 7600 15000

    800

    800

    860

    5 4200x12000x3000 48.0 2000 5.5

    Direct

    Reduce

    4

    400

    125×8

    250x4

    40×4

    50×4

    50×4

    ∠62 6100 15100
    6 4200×12000×3100 52.5 2000 5.5 6300 15600
    10 4400×12000×3600 72.0 2400 7.5 7200 16000
    25 4800x12800×4100 80.0 2800 11.0 8100 16900

    900

    900

    960

    5 4000x16200x3000 54.0 1800 4.0

    Direct

    Reduce

    6

    400

    125×12

    200×6

    40×6

    50×6

    50×6

    ∠65 6600 13800
    6 4000x16200x3100 57.5 2000 4.0 7000 16000
    10 4200×16200×3600 67.5 2000 5.5 8600 16800
    25 4400×16200×4100 90.0 2400 7.5 10000 17600

    1000

    1000

    1230

    5 4200×15000×3100 62.5 5000 5.5

    Direct

    Reduce

    5

    400

    125×10

    250x5

    40×5

    50×5

    50x5

    ∠68 7600 16600
    6 4200×15000×3100 65.5 2000 5.5 7800 16900
    10 4200×15000×3100 75.5 2400 7.5 9100 18900
    25 4800x16000x4100 98.0 2800 11.0 10100 20700

    1200

    1200

    1350

    5 4200x18000×3000 100 2000 5.5

    Direct

    Reduce

    6

    500

    125×12

    2506

    40%6

    50×6

    50x6

    ∠68 9400 21000
    6 4200x18000×3100 115 2000 5.5 9600 22000
    10 4400x18000x3600 140 2400 7.5 10100 23000
    25 4800×19200×4100 210 2800 11.0 12200 26000

    1500

    1500

    1650

    5 4400×19800×3000 100 2400 7.5 Reduce

    6

    500

    125x12

    250x6

    40x6

    65×6

    65x6

    ∠68 10100 23000
    6 4400×19800×3100 115 2400 7.5 11500 25000
    10 4800×19800×3600 140 2800 11.0 12500 31000
    25 4800x19800×4100 210 2800 11.0 14500 36000

    1800

    1800

    1805

    5 4200×27000×3000 100 2000 4.0

    Direct

    Reduce

    9

    550

    125x18

    250x9

    40x9

    50x9

    50x9

    ∠68 14200 22500
    6 1200×27000×3100 120 2000 5.5 15000 24000
    10 4400×27000×3600 150 2400 7.5 17000 35000
    25 4800×28800×4100 240 2800 11.0 20000 56000

    Cooling Tower Installation Requirements:

    The cooling tower should be installed on a flat ground or building platform with good natural ventilation, no building obstruction at the air inlet and no heat impact. There must be no objects at 1.5-2 meters at the air inlet to ensure smooth natural wind.
    The cooling tower should be installed on a horizontal foundation to ensure that the overall mass of the cooling tower is evenly stressed on the foundation pier.

    Quality Stainless Steel Induced Draft Cross Flow Open Circuit Cooling Tower for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuxi Weishi Industrial Complete Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)